NIST release EHR evaluation guidance

March 22, 2012 - An important aspect of any product is how easily someone can use it for its intended purpose, also known as usability. Electronic health records (EHR) that are usable have the potential to improve patient care, which is why the National Institute of Standards and Technology (NIST) has outlined formal procedures for evaluating the usability of EHR systems.

The proposed usability protocol encourages a user-centered approach to the development of EHR systems. It provides methods to measure and address critical errors in user performance before those systems are deployed in a medical setting.

"This guidance can be a useful tool for EHR developers to demonstrate that their systems don't lead to use errors or user errors," said NIST researcher Matt Quinn. "It will provide a way for developers and evaluators to objectively assess how easy their EHR systems are to learn and operate, while maximizing efficiency."

The protocol is a three-step process consisting of an analysis of how the application functions, expert review, and validation testing of the

user interface to make sure it works as intended.

The protocol includes general steps and guidance for evaluating an EHR user interface from a clinical perspective-does it contain, collect and display the information it needs to-and human factors perspectives-can the user understand it and easily find needed information. The interface is then tested by representative user groups performing realistic tasks.

"We hope this encourages system developers to apply human factors best practices and incorporate user-centered design processes," said Quinn. "These practices and processes have proven records in industries such as aviation, military systems, transportation, nuclear power, and others where safety is a concern."

The EHR Usability Evaluation Protocol (EUP), Technical Evaluation, Testing and Validation of the Usability of Electronic Health Records (NIST Interagency Report 7804), is available at www.nist.gov/healthcare/usability/index.cfm. A draft version of the document was released for public comment in September 2011. The current version incorporates feedback received.

Share on your social network

Comments


Be the first to comment on this Article

Name
 
Location
 
Comment
Limited to 500 Characters. You have characters left.
To submit your comment, please type the security word shown in the picture. imgCaptcha
Remember information
 
 

 

Chiropractic Economics Magazine - A Chiropractic Publication

Chiropractic News



Campaign for Chiropractic

Chiropractic Economics ©2014 | 5150 Palm Valley Rd. Suite 103 | Ponte Vedra Beach, FL 32082 | P:904.285.6020 F:904.285.9944